Hygiene Monitoring
Hygiene Monitoring
Hygiene Monitoring

Product Survey Batch Monitoring Systems



Every sterilization cycle is unique. Therefore every cycle has to be monitored. BAG batch monitoring systems are used to monitor the critical parameters of each cycle and can be used for load release assurance.

download area



Batch Monitoring System BAG-RePac


Product Description Packaging unit REF
BAG-RePac
121°C

Batch Monitoring System for steam sterilization at 121°C + documentation card, for fractionated vacuum sterilizers 300 7541
BAG-RePac
134°C
Batch Monitoring System for steam sterilization at 134°C + documentation card, for fractionated vacuum sterilizers 300 7542
BAG-RePac 18 Batch Monitoring System for steam sterilization at 134°C / 18 minutes + documentation card, for fractionated vacuum sterilizers 300 7553
BAG-RePac
Bulk-Kits 121°C
Contents:
1.500 RePac-Indicators 121°C,
100 paper stacks for 15 uses each
1500 75475
BAG-RePac
Bulk-Kits 134°C
Contents:
1.500 RePac-Indicators 134°C,
100 paper stacks for 15 uses each
1500 75485
BAG-RePac
Bulk/Mix
Contents:
1.200 RePac-Indicators 134°C,
300 RePac-Indicators 121°C,
100 paper stacks for 15 uses each
1500 75505
BAG-RePac
Bulk-Kits 18
Contents:
1.500 RePac-Indicators 134°C,
100 paper stacks for 15 uses each
1500 75545
BAG-RePac
Metal PCD
Process challenge device for BAG-RePac indicators 1 7540







Batch Monitoring System BAG-HeliPac


Product Description Packing unit REF
BAG-HeliPac
121°C – Starterset I

Batch Monitoring System for steam sterilization at 121°C for fractionated vacuum sterilizers incl. helix PCD 1200 7571
BAG-HeliPac
134°C –
Starterset I
Batch Monitoring System for steam sterilization at 134°C for fractionated vacuum sterilizers incl. helix PCD 1200 7572
BAG-HeliPac
18 Min. –
Starterset I
Batch Monitoring System for steam sterilization at 134°C / 18 minutes for fractionated vacuum sterilizers incl. helix PCD 1200 7573
BAG-HeliPac
Mix –
Starterset I
Batch Monitoring System for steam sterilization at 121°C (300 indicators) and 134°C (900 indicators) for fractionated vacuum sterilizers incl. helix PCD 1200 7574
BAG-HeliPac
121°C –
Starterset II
Batch Monitoring System for steam sterilization at 121°C for fractionated vacuum sterilizers incl. helix PCD 600 75716
BAG-HeliPac
134°C –
Starterset II
Batch Monitoring System for steam sterilization at 134°C for fractionated vacuum sterilizers incl. helix PCD 600 75726
BAG-HeliPac
18 Min. –
Starterset II
Batch Monitoring System for steam sterilization at 134°C / 18 minutes for fractionated vacuum sterilizers incl. helix PCD 600 75736
BAG-HeliPac
121°C
Refill
Refill Kit for BAG-HeliPac 121°C 300 75711
BAG-HeliPac
134°C
Refill
Refill Kit for BAG-HeliPac 134°C 300 75721
BAG-HeliPac 18
Refill
Refill Kit for BAG-HeliPac 134°C/18 min. 300 75731